Abstract
VOF simulation results for ferrofluid droplet generation in a co-flowing microchannel under a uniform axial field (40–160 kA/m) are analysed: flow-regime maps, snapshots at t = 0.06 and 0.12 s, and sweeps of interfacial tension (0.0015–0.012 N/m) and viscosity ratio (0.05–0.57). The field barely moves the jetting/dripping boundary (one extra dripping cell), raises droplet frequency by 6–16% and VD/VM from 1.8 to 2.0 at low viscosity ratio, but lowers frequency by up to 30% at high viscosity ratio. Droplet aspect ratio is inferred to grow by 24–29%.
Key analytical results
Sphere in a uniform field (\(k=(\mu_r-1)/(\mu_r+2)\)):
$$H_r=H_0\Big(1+2k\frac{R^3}{r^3}\Big)\cos\theta,\qquad H_\theta=-H_0\Big(1-k\frac{R^3}{r^3}\Big)\sin\theta$$Prolate-spheroid equilibrium from the Gibbs energy, with \(Bo_m=\mu_0H_0^2R_0/\sigma\):
$$\frac{\mathcal E}{4\pi R_0^2\sigma}=\frac{S}{4\pi R_0^2}-\frac{Bo_m}{6}\,\frac{\chi}{1+N\chi}$$Magnetically modified Rayleigh dispersion relation for an axial thread (\(x=kR\)):
$$s^2=\frac{\sigma}{\rho R^3}\frac{xI_1(x)}{I_0(x)}\Big[1-x^2-Bo_m\Psi(x)\Big],\quad \Psi=\frac{(\mu_r-1)^2xI_0(x)}{\mu_rI_1(x)+I_0(x)K_1(x)/K_0(x)}$$Mass-conservation estimate of the field-induced aspect-ratio change:
$$\frac{AR_H}{AR_0}=\Big(\frac{L_H}{L_0}\Big)^{3/2}\Big(\frac{F_H}{F_0}\Big)^{1/2}$$Reference case (digitised)
| H (kA/m) | 0 | 40 | 80 | 120 | 160 |
|---|---|---|---|---|---|
| LD/WC | 0.31 | 0.35 | 0.35 | 0.35 | 0.35 |
| FD (Hz) | 139.5 | 148 | 153 | 157 | 162 |
| VD/VM | 1.8 | 1.8 | 2.0 | 2.0 | 2.0 |
| AR ratio | 1 | 1.24 | 1.26 | 1.27 | 1.29 |
Scaling correlations
$$\frac{L_D}{W_C}=0.2868\,Ca^{-0.05},\quad F_D=1023.7Ca^2-532.22Ca+163.23,\quad \frac{V_D}{V_M}=12.431Ca^2-6.629Ca+2.0273$$This page is a summary. The full 11-page paper (all derivations, contour diagrams, figures and references) is the compiled paper.pdf / paper.tex from the analysis. Values were digitised from images; solver settings and fluid properties were not available, so analytical plots use illustrative susceptibilities.